A wall switch panel size is a regional standard that describes two things at once: the visible faceplate dimensions and, more importantly for replacement work, the wall box and screw spacing hidden behind it. Three sizes cover most of the world — the 86 type used across Europe and much of Asia, the 118 type used in North America and Australia, and the 147 type used in Pakistan and the Middle East. Choosing the wrong one is not a cosmetic mistake: the plate will not sit flush and the mounting holes will not line up.
The three panel sizes at a glance
| Type | Faceplate size | Typical regions | Supply and outlet standard | Fixing notes |
|---|---|---|---|---|
| 86 type | 86 x 86 mm | UK, most of Europe, China, much of Asia | 230 V / 50 Hz; Type E and F (Schuko) | 60 mm fixing centres; the most widely swapped size |
| 118 type | About 118 x 72 to 76 mm (see note below) | USA, Canada, Australia | 110 to 120 V / 60 Hz; NEMA | Wider screw spacing; no-neutral wiring is common in older homes |
| 147 type | 147 x 86 x 40 mm | Pakistan, Middle East | 230 V / 50 Hz | Largest format; used where several gangs and a deeper chassis are needed |
A note on the 118 size. You will see both 118 x 72 mm and 118 x 76 mm quoted for the same panel family. Both figures can be correct, because some datasheets measure the chassis while others measure the outer faceplate. Measure your own wall box rather than trusting either number.
The 86 type: Europe, the UK and most of Asia
The 86 type is the most common format worldwide and the easiest to replace. The plate is square at 86 x 86 mm and the two fixing screws sit 60 mm apart. It runs on 230 V at 50 Hz with Type E or F sockets. The UK is the one exception worth remembering: it uses the same 86 x 86 mm plate size, but any unit that includes a socket must meet BS 1363 with a 13 A pin layout and carry UKCA marking. A European 86 plate is therefore not automatically legal in a UK installation, even though it physically fits.
The 118 type: North America and Australia
The 118 type is a wider, shallower plate used with US and Canadian single-gang boxes on 110 to 120 V at 60 Hz. The practical gotcha here is not the dimensions but the wiring: older 118-type homes frequently have no neutral wire in the switch box. That single fact decides whether a given smart switch will work at all, and no amount of adapter hardware fixes a missing conductor.
The 147 type: Pakistan and the Middle East
The 147 type is a large format plate, roughly 147 x 86 mm and about 40 mm deep, common in Pakistan and across Middle Eastern markets. The extra face area is used for high gang counts in one frame, which is why it turns up in large homes and hotel projects. It is supplied on 230 V / 50 Hz.
How to check what you have before ordering
- Switch the breaker off at the consumer unit, then photograph the existing wiring before you disconnect anything.
- Pull the old plate and measure it edge to edge, then measure the distance between the fixing screw centres rather than relying on the plate outline alone.
- Check whether a neutral wire is present in the box. This matters more than any dimension, especially for 118 type installations.
- Check box depth. A smart plate carries electronics behind the glass and needs noticeably more room than a mechanical switch.
- If the plate includes a socket, confirm the unit matches the regional outlet standard and its certification, not just the panel size.
Frequently Asked Questions
Can I replace an 86 plate with a 118 plate?
Not without replacing the wall box. The two sizes have different screw spacing and different external dimensions, so the plate will not mount. Changing between types is a wall-box job, not a faceplate swap.
Is the UK the same 86 size as mainland Europe?
The plate dimensions are the same, but the compliance requirements are not. UK installations need BS 1363 sockets with the 13 A pin layout and UKCA marking, so a mainland European 86 plate is not an acceptable substitute even though it fits the box.
Why do some listings say 118 x 72 mm and others 118 x 76 mm?
Because they are measuring different things. One figure describes the chassis and the other the outer faceplate. The difference of a few millimetres is genuine and not a specification error, which is why the existing wall box should always be measured directly.
Do smart switches need a neutral wire?
Some do and some do not, and this is the most common reason a replacement fails. Switches designed for no-neutral installations draw a small leakage current through the load, which is why they can behave oddly with LED lamps. Switches that need a neutral are usually more stable but need the conductor present in the box.
Can a smart switch go into an old house without rewiring?
Often yes, provided the box has enough depth for the electronics and you pick a model designed for no-neutral wiring if there is no neutral present. If the box is too shallow or genuinely has no neutral and the load is very low wattage, an electrician may need to run additional cabling.
Does the 147 type fit standard wall boxes?
No. The 147 format is substantially larger than both the 86 and 118 types and is intended for installations built around it. In Pakistani and Middle Eastern markets the boxes are specified accordingly, but retrofitting a 147 plate into another standard’s box is not practical.
Where do I find switches for each size?